西门子模块SIEMENS益阳PLC代理商
西门子3TL系列中压接触器代理商
SIPLUS CMS1200 SM 1281 Condition Monitoring
6AT8007-1AA31-0AA0
SIPLUS CMS1200 X 工具捆绑包 组成部分: SM1281 状态监控, SM1281 屏蔽支架组件, X 工具*版V05.00, X 工具分析库 V05.00
6AT8007-1AA10-0AA0 SIPLUS CMS1200 SM1281 状态监控,用于 SIMATIC S7-1200 4 个 IEPE 振动通道 1个数字输入端,用于 转速采集 |
概述
SIPLUS CMS1200 SM 1281 Condition Monitoring forms part of SIMATICS7-1200 and is used for the:
Monitoring of motors, generators, pumps, fans, or other mechanicalcomponents
Recording and analysis of vibrations
Expansion capability of up to 7 modules
设计
SIPLUS CMS1200 SM 1281 Condition Monitoring includes:
Integrated diagnostics software
4 IEPE interfaces for vibration sensors
1 speed input
The following accessories can also be ordered, see"Accessories":
SIPLUS CMS1200 SM 1281 shield clamp set for EMC-compliant cableconnection
VIB-SENSOR vibration sensor for recording vibrations
CABLE-MIL connecting cable, several cable length available
功能
SIPLUS CMS1200 SM 1281 Condition Monitoring comes with thefollowing fixed functional scope as standard:
Characteristic values (bearing, vibration monitoring)
Fre analysis using FFT, H‑FFT
Trend analysis
Limit value monitoring of frequency bands
Recording with time stamp of trend values, raw data, fre, alarm log
Simple localization of damage using fingerprint comparison
Output of system and status messages
Extraction of raw data for further diagnoses
Web server
技术规范
Article number | 6AT8007-1AA10-0AA0 | |
---|---|---|
SM1281_Condition_Monitoring | ||
Generalinformation | ||
Product typedesignation | SM1281 | |
Productdescription | S7-1200module for the monitoring of vibrations on mechanical componentsbased on parameters and fre analysis functions | |
Installationtype/mounting | ||
Mountingtype | Rail or wallmounting | |
Mountingposition | Horizontal,vertical | |
Recommendedmounting position | Horizontal | |
Supplyvoltage | ||
Type ofsupply voltage | DC | |
Rated value(DC) | 24 V | |
permissiblerange, lower limit (DC) | 20.4 V | |
permissiblerange, upper limit (DC) | 28.8 V | |
Inputcurrent | ||
Currentconsumption, typ. | 200 mA | |
Currentconsumption, max. | 250 mA | |
frombackplane bus 5 V DC, typ. | 80 mA | |
frombackplane bus 5 V DC, max. | 85 mA | |
Powerloss | ||
Power loss,typ. | 4.8 W | |
Memory | ||
Total memorycapacity | 1 Gbyte | |
Hardwareconfiguration | ||
Design ofhardware configuration | Modular, upto 7 modules per CPU | |
Speedinput | ||
Number ofspeed inputs | 1 | |
Inputvoltage | ||
● 24 VDC digital | Yes | |
Sensorinput | ||
Number ofIEPE sensor inputs | 4 | |
Samplingfrequency, max. | 46 875 Hz | |
Interfaces | ||
Type of datatransmission | Export of rawdata as WAV file for further analysis (e.g. using CMS X-Tools) canbe downloaded via browser/FTP, online data transfer to CMSX-Tools | |
Ethernetinterface | ||
Protocols | ||
Buscommunication | ||
Webserver | ||
● HTTP | ||
Interrupts/diagnostics/status information | ||
Alarms | ||
● Diagnostic alarm | ||
Diagnosticsindication LED | ||
● forstatus of the inputs | ||
● formaintenance | ||
● Statusindicator digital input (green) | No | |
IntegratedFunctions | ||
Monitoringfunctions | ||
● Monitoring of the sensor inputs | Yes; Cablebreak and short-circuit | |
● Vibration characteristic monitoring via RMS value of thevibration speed | ||
● Vibration characteristic monitoring via RMS value of thevibration acceleration | ||
● Vibration characteristic monitoring via diagnosticcharacteristic value | ||
● Fre monitoring via vibration speedspectrum | ||
● Fre monitoring via vibration accelerationspectrum | ||
● Fre monitoring via envelope curveanalysis | ||
Measuringfunctions | ||
● Physical measuring principle | Vibrationacceleration | |
Measuringrange | ||
— Measurement range vibration frequency, min. | 0.1 Hz | |
— Measurement range vibration frequency, max. | 10 000 Hz | |
Standards,approvals, certificates | ||
Certificateof suitability | CE | |
CE mark | ||
China RoHScompliance | ||
Ambientconditions | ||
Free fall | ||
● Fallheight, max. | 0.3 m;five times, in product package | |
Ambienttemperature during operation | ||
● horizontal installation, min. | -20 °C | |
● horizontal installation, max. | 60 °C | |
● vertical installation, min. | ||
● vertical installation, max. | 45 °C | |
Ambienttemperature during storage/transportation | ||
● Storage, min. | -40 °C | |
● Storage, max. | 70 °C | |
● Transportation, min. | ||
● Transportation, max. | ||
Air pressureacc. to IEC 60068-2-13 | ||
● Operation, min. | 795 hPa | |
● Operation, max. | 1 080 hPa | |
● Storage/transport, min. | 660 hPa | |
● Storage/transport, max. | ||
Software | ||
Browsersoftware required | Web browserMozilla Firefox (ESR31) or Microsoft Internet Explorer (10/11) | |
Connectionmethod | ||
re connector | ||
Design ofelectrical connection | Screwconnection | |
Mechanics/material |